F68V/Y Vapor Removal Filters
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-3-9
Typical Performance Characteristics
Technical Data
Fluid: Compressed air
Maximum pressure: 250 psig (17 bar)
Operating temperature*: 0° to 150°F (-20° to 65°C)
* Air supply must be dry enough to avoid ice formation at temperatures below +35°F
(+2°C).
Air quality: Within ISO 8573-1, Class 1 (oil content) when installed
downstream of an oil removal filter
Maximum remaining oil content in outlet air: 70°F (0.003 mg/m
3
at 20°C)
Maximum flow at 90 psig (6.3 bar) inlet pressure to maintain stated oil
removal performance:
1/2" ports: 53 scfm (25 dm
3
/s)
3/4" ports: 74 scfm (35 dm
3
/s)
1" ports: 127 scfm (60 dm
3
/s)
Nominal bowl sizes:
1 quart US (1 liter)
1 pint US (0.5 liter)
Required pre-filter: Oil removal filter with equivalent pipe size and flow
capacity equal to or greater than the vapor removal filter. It is
recommended that a general purpose filter with a 5µm element be
installed upstream of the oil removal filter.
Materials:
Body: Aluminum
Yoke: Aluminum
Bowl: Aluminum
Element: Activated carbon and aluminum
Elastomers: Synthetic rubber
All Dimensions in Inches (mm)
Inlet Pressure Maximum Flow
*
F68V F68Y
1/2" Ports 1" Ports
psig (bar) scfm (dm
3
/s) scfm (dm
3
/s)
36 (2.5) 33.3 (15.7) 80.1 (37.8)
58 (4) 42.4 (20) 101.8 (48)
90 (6.3) 53 (25) 127.2 (60)
116 (8) 60 (28.3) 143.7 (67.8)
150 (10) 66.8 (31.5) 160.3 (75.6)
* Maximum flow to maintain stated oil removal performance.
Service kit includes element seal and bowl seal.
Service Kits
Item Type Part Number
Service kit Seal and Gasket 4380-302
Replacement element
Standard Flow (F68V) 665-72
High Flow (F68Y) 665-70
Comentários a estes Manuais