F72V Oil Vapor Removal Filter
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-3-3
Technical Data
Fluid: Compressed air
Maximum pressure
Transparent bowl: 150 psig (10 bar)
Metal bowl: 250 psig (17 bar)
Operating temperature*
Transparent bowl: 0° to 125°F (-20° to 50°C)
Metal bowl: 0° to 150°F (-20° to 65°C)
* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Required prefilter: Norgren oil removal filter with equivalent pipe size and flow
capacity equal to or greater than the vapor removal filter.
Air quality: Within ISO 8573-1, Class 1** (oil content) when installed downstream of
an oil removal filter
** See ALE-1-G for specification details.
Maximum remaining oil content in outlet air: 0.003 ppm at 70°F (20°C)
Maximum flow at 90 psig (6.3 bar) inlet pressure to maintain stated oil removal
performance: 3.4 scfm (1.6 dm
3
/s)
Nominal bowl size
2.2 fluid ounce (65 ml)
Materials
Body: Zinc
Bowl
Transparent: Polycarbonate
Guard for transparent bowl: Zinc
Metal: Zinc
Element: Activated carbon and polycarbonate
Elastomers: Nitrile
Typical Performance Characteristics
Service kit includes element seal and bowl seal.
Service Kits
Item Type Part Number
Service kit Seal and Gasket 4380-500
Replacement element Adsorbing 4241-01
† Minimum clearance required to remove bowl.
All Dimensions in Inches (mm)