Vista de página 0
See Section ALE-24 for Accessories
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-5-2
R06
Compact design, corrosion resistant construction
Brass body with choice of plastic or brass bonnet
Plastic bonnet equipped with low torque, non-rising
pressure adjusting knob. Snap action knob locks
pressure setting when pushed in
Brass bonnet equipped with pressure adjusting
screw
Non-relieving models for air and water service
Relieving models for air service allow reduction of
outlet pressure even when the system is dead-ended
Can be disassembled without the use of tools or
removal from the air or water line
Miniature Brass Body Regulator
Water and Compressed Air Service
1/8" and 1/4" PTF Port Sizes
ISO Symbols
Relieving Non relieving
Alternative Models
0R 6
-
-
Port Size Substitute
1/8" 1
1/4" 2
Threads Substitute
PTF A
Outlet Pressure Adjustment Range† Substitute
1 to 10 psig (0.1 to 0.7 bar) A
5 to 50 psig (0.3 to 3.5 bar) E
5 to 100 psig (0.3 to 7 bar) K
5 to 125 psig (0.3 to 8.6 bar) L
Gauges Substitute
With G
Without N
Diaphragm Substitute
Relieving R
Non relieving N
Bonnet Substitute
Plastic 21
Brass 22
Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
Ordering Information. Models listed include PTF threads, plastic bonnet with knob adjustment, non-relieving diaphragm, 5 to 100 psig (0.3 to 7 bar)
outlet pressure adjustment range†, and without gauge.
Port Model Flow
*
scfm (dm
3
/s) Flow
**
gpm (lpm) Weight lb (kg)
1/8" PTF R06-121-NNKA 12 (5.7) 1.3 (4.9) 0.2 (0.09)
1/4" PTF R06-221-NNKA 12 (5.7) 1.3 (4.9) 0.2 (0.09)
* Approximate flow with 100 psig (7 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.
** Approximate flow with100 psig ( 7 bar) inlet pressure, 60 psig (4 bar) set pressure and a 15 psig (1 bar) droop from set.