Norgren Filter Contents Manual do Utilizador Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 53
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
F64C/H Oil Removal (Coalescing) Filters
Littleton, CO USA Phone 303-794-2611 www.norgren.com
ALE-2-11
Typical Performance Characteristics
Inlet Pressure Maximum Flow
F64C F64H
psig (bar) scfm (dm
3
/s) scfm (dm
3
/s)
15 (1) 14 (6.4) 24 (11.2)
45 (3) 23 (11.0) 41 (19.3)
70 (5) 30 (14.3) 53 (24.9)
90 (6.3) 34 (16.0) 59 (28.0)
100 (7) 36 (16.9) 63 (29.5)
130 (9) 40 (19.1) 71 (33.5)
Maximum flow to maintain stated oil removal performance.
Service Kits
Item Type Part Number
Service kit F64C/H 4380-200
Service kit (pre-filter) F64G 4380-200
Element F64G (pre-filter) 5 µm 4338-01
Element F64C Coalescing 4344-01
Element F64H Coalescing 4344-02
Replacement sight glass
Prismatic (standard) 4380-040
Pyrex 4380-041
Replacement drains
Automatic 3000-97
Manual 684-84
Service kit includes port seals, louver o-ring, bowl o-ring and drain gasket.
4.13 (105)
1.46
(37)
2.91
(74)
F64C, Automatic Drain
9.40 (239)††
1.46
(37)
6.45 (164)
2.32 (59)
7.05 (179)
F64C, 1/4 Turn Manual Drain
10.00 (254)††
6.18" (157) for 3/4" ports.
†† Minimum clearance required to remove unit.
11.57 (294)††
8.58 (218)
F64H, Automatic Drain
F64H, 1/4 Turn Manual Drain
12.20 (310)††
9.21 (234)
Service
Indicator
Technical Data
Fluid: Compressed air
Maximum pressure: 250 psig (17 bar)
Operating temperature*: 0° to +150°F (-20° to +65°C)
* Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C).
Particle removal: 0.01 µm
Air quality: Within ISO 8573-1, Class 1 (particulates) and Class 2 (oil content).
Maximum remaining oil content: 0.01 mg/m
3
at +70°F (+20°C) with an inlet
concentration of 17 mg/m
3
.
Maximum flow at 90 psig (6.3 bar) inlet pressure to maintain stated oil removal
performance:
1/2" ports: 74 scfm (35 dm
3
/s)
3/4" ports: 74 scfm (35 dm
3
/s)
1" ports: 127 scfm (60 dm
3
/s)
1/4 turn manual drain connection: 1/8" pipe thread
Automatic drain connection: 1/8" pipe thread
Automatic drain operating conditions (float operated):
Bowl pressure required to close drain: Greater than 5 psig (0.3 bar)
Bowl pressure required to open drain: Less than 3 psig (0.2 bar)
Minimum air flow required to close drain: 2 scfm (1 dm
3
/s)
Manual operation: Depress pin inside drain outlet to drain bowl
Nominal bowl size:
1 pint U.S. (0.5 liter)
1 quart U.S. (1 liter)
Materials:
Body: Aluminum
Yoke: Aluminum
Bowl: Aluminum
Liquid level indicator: Pyrex
Element: Synthetic fibre and polyurethane foam
Elastomers: Synthetic rubber
Service life indicator:
Body: Transparent nylon
Internal parts: Acetal
Spring: Stainless steel
Elastomers Nitrile
An automatic drain is a two-way valve, which will close when the system is
pressurized. The drain opens when the float rises due to accumulated liquid
and on depressurization.
Vista de página 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 52 53

Comentários a estes Manuais

Sem comentários