ALE-7-3
All Dimensions in Inches (mm)
R30M Manifold Regulators
Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487
Technical Data
Fluid: Compressed air or water
Maximum pressure: 150 psig (10 bar)
Operating temperature*: 23° to 104°F (-5° to 40°C)
* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Approximate flow at 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure
and a droop of 15 psig (1 bar) from set: 17 scfm (8 dm
3
/s)
Gauge port:
(can be used as additional outlet port)
10 mm OD tube with 10 mm OD tube main ports
8 mm OD tube with 8 mm OD tube main ports
Two inlet ports:
10 mm OD tube or 8 mm o/d tube
One outlet port:
10 mm OD tube with 10 mm OD tube inlet
8 mm OD tube with 8 mm OD tube inlet
Materials:
Body: Acetal
Bonnet: Acetal
Valve: Brass/nitrile
Elastomers: Nitrile
Valve seat: Acetal
Panel mounting hole diameter: 1.19" (30 mm)
Maximum panel thickness: 0.25" (6 mm)
Typical Manifold Regulator Application